Features: The C-270 is
constructed of high strength, aircraft grade, aluminum alloy forgings
with a wear resistant anodized finish. The blades on the C-270 Cutter
are forged steel. The C-270 Cutter has a “D” handle that can be rotated
360 degrees or removed when working in confined spaces. The C-270 Cutter
has a variable speed, “deadman” control with load holding capability and
over-pressurization relief.
|
C270 Specifications |
| NFPA Level Rating |
A7/B8/C7/D8/E9 |
| Length (in/cm) |
31/789 |
| Width (in/cm) |
8.7/220 |
| Height (in/cm) |
8.7/221 |
| Weight (lbs/kg) |
38/17.3 |
| Opening (in/cm) |
11/278 |
| Opening Time (sec) |
3.4 |
| Closing Time (sec) |
3.9 |
Operating Pressure
(max. psi/bar) |
10,500/720 |
Cutting Force
(max. lbs/kN) |
157,000/699 |
| NFPA Compliant |
Yes |
| Part Number |
ART.593.209.2 |
Rotating and
Removable Handle
The C-270 cutter comes with an adjustable and removable "D" shaped
handle. This handle can be rotated 360o or completely removed
for use in confined spaces. Being able to rotate the handle allows the
cutter to be easily using in any position. Professional Note: Most
experienced personnel keep the handle slightly loose. They routinely
adjust the handle position throughout a rescue.
Push Button Control
One of the most beneficial features of the C-270 Cutter is the push
button control. The control is a variable speed device allowing the
cutter to be "feathered." This controls the speed of the cutter when
opening and closing. The control is fitted with a guard to protect the
rescuer's hands from obstructions and offers protection to the connecting
hoses of the tool.
Over-Pressurization
Relief Valve
If the couplers have not been properly engaged or there is a blockage
in the return line, preventing the fluid flow back to the unit, a relief
in the control handle automatically releases fluid. This causes a low
pressure fluid leak from the hole between the hoses. The power unit is
switched to the neutral position and the couplings can be connected or the
blockage removed. Ordinary tools that do not have this device can
literally explode.